{"id":4280,"date":"2026-05-23T12:58:51","date_gmt":"2026-05-23T04:58:51","guid":{"rendered":"https:\/\/lijmedtube.com\/?post_type=product&#038;p=4280"},"modified":"2026-05-23T13:23:46","modified_gmt":"2026-05-23T05:23:46","slug":"custom-bent-non-coring-needle-for-iv-indwelling-cannula","status":"publish","type":"product","link":"https:\/\/lijmedtube.com\/de\/produkt\/custom-bent-non-coring-needle-for-iv-indwelling-cannula\/","title":{"rendered":"Benutzerdefinierte nicht-bohrende Huber-Nadel"},"content":{"rendered":"<h2 data-pm-slice=\"1 1 []\" data-rm-block-id=\"block-1\"><span style=\"color: #0c4d8a;\">Overview<\/span><\/h2>\n<p data-rm-block-id=\"block-3\">Our custom bent non-coring needles are high-performance OEM components specifically designed for modern intravenous (IV) indwelling systems and cannula manufacturing. By combining our proprietary micro-tubing bending technology with ultra-sharp, non-traumatic needle grinding, we provide medical device manufacturers with the perfect core components. These needles ensure maximum patient comfort through effortless penetration while maintaining impeccable geometric stability and fluid dynamics.<\/p>\n<h2 data-pm-slice=\"1 1 []\" data-rm-block-id=\"block-5\"><span style=\"color: #0c4d8a;\">Anwendungen<\/span><\/h2>\n<h2 data-rm-block-id=\"block-6\"><\/h2>\n<h4 data-rm-block-id=\"block-7\">Specialized Bending &amp; Forming for IV Systems<\/h4>\n<ul>\n<li data-rm-block-id=\"block-9\"><b data-path-to-node=\"16,0,0\" data-index-in-node=\"0\">Zero-Restriction Internal Channels:<\/b> Our specialized bending process ensures the inner diameter remains perfectly round and smooth at the bend, preventing any flow restriction or wire obstruction.<\/li>\n<li data-rm-block-id=\"block-10\"><b data-path-to-node=\"16,1,0\" data-index-in-node=\"0\">Multiform Configurations:<\/b> We support 90\u00b0 bends, U-shapes, offset steps, and multi-segment continuous bends tailored to fit unique hub designs or automated safety retraction mechanisms.<\/li>\n<li data-rm-block-id=\"block-11\"><b data-path-to-node=\"16,2,0\" data-index-in-node=\"0\">Perfect Bevel Alignment:<\/b> The needle tip bevel angle can be precisely aligned with the bending direction according to your exact blueprints.<\/li>\n<\/ul>\n<h4 data-rm-block-id=\"block-13\">Non-Coring Penetration Technology<\/h4>\n<ul data-path-to-node=\"11\">\n<li>\n<p data-path-to-node=\"11,0,0\" data-rm-block-id=\"block-15\"><b data-path-to-node=\"18,0,0\" data-index-in-node=\"0\">Tissue-Friendly Design:<\/b> The needle tip is engineered to displace tissue rather than cutting a core out of it, drastically reducing the risk of phlebitis and secondary bleeding.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"11,1,0\" data-rm-block-id=\"block-16\"><b data-path-to-node=\"18,1,0\" data-index-in-node=\"0\">Ultra-Thin Wall Options:<\/b> Utilizing medical-grade stainless steel with ultra-thin walls to maximize the inner flow rate while maintaining the structural rigidity required for successful first-stick venipuncture.<\/p>\n<\/li>\n<\/ul>\n<h3 data-pm-slice=\"1 1 []\" data-rm-block-id=\"block-18\"><span style=\"color: #0c4d8a;\">Warum sollten Sie sich f\u00fcr LIJ Med Tube entscheiden?<\/span><\/h3>\n<ul data-pm-slice=\"3 1 []\">\n<li data-rm-block-id=\"block-20\"><b data-path-to-node=\"5,1,0,0\" data-index-in-node=\"0\">Der Komplettanbieter f\u00fcr medizinische OEM-\/ODM-L\u00f6sungen:<\/b> Von der Analyse komplexer technischer Konstruktionszeichnungen bis hin zur Serienfertigung in gro\u00dfen St\u00fcckzahlen liefern wir durchg\u00e4ngige L\u00f6sungen f\u00fcr Pr\u00e4zisionsbauteile, die vollst\u00e4ndig in unserem eigenen Haus hergestellt werden.<\/li>\n<\/ul>\n<ul data-pm-slice=\"3 1 []\">\n<li data-rm-block-id=\"block-21\"><b data-path-to-node=\"5,1,1,0\" data-index-in-node=\"0\">HMLV &amp; ma\u00dfgeschneiderte Materiall\u00f6sungen:<\/b> Wir sind auf Projekte mit gro\u00dfer Produktvielfalt und geringen St\u00fcckzahlen (HMLV) spezialisiert. Ganz gleich, ob Sie Mikroschl\u00e4uche ben\u00f6tigen <b data-path-to-node=\"5,1,1,0\" data-index-in-node=\"118\">bis auf 0,06 mm<\/b>, Sonderlegierungen (Nitinol, 316L) oder komplexe Geometrien wie geschlitzte \u201eSnake-Bone\u201c-Rohre \u2013 wir passen uns flexibel an Ihre individuellen Forschungs- und Entwicklungsanforderungen an.<\/li>\n<\/ul>\n<ul data-pm-slice=\"3 1 []\">\n<li data-rm-block-id=\"block-22\"><b data-path-to-node=\"5,1,3,0\" data-index-in-node=\"0\">Medizinische Qualit\u00e4t und l\u00fcckenlose R\u00fcckverfolgbarkeit:<\/b> Wir arbeiten nach strengen Qualit\u00e4tsmanagementsystemen auf medizinischem Niveau und garantieren die R\u00fcckverfolgbarkeit des Materials 100%, mikroskopische Konsistenz (SEM-gepr\u00fcft) sowie vollst\u00e4ndige weltweite Konformit\u00e4t.<\/li>\n<\/ul>\n<ul data-pm-slice=\"3 1 []\">\n<li data-rm-block-id=\"block-23\"><b data-path-to-node=\"5,1,4,0\" data-index-in-node=\"0\">Skalierbare Kosteneffizienz:<\/b> Durch den Einsatz automatisierter Fertigung und hochoptimierter Herstellungsprozesse bieten wir erstklassige medizinische Qualit\u00e4t ohne den daf\u00fcr \u00fcblichen hohen Preis und sichern so Ihren Wettbewerbsvorteil.<\/li>\n<\/ul>\n<h3 data-pm-slice=\"1 1 []\" data-rm-block-id=\"block-25\"><span style=\"color: #0c4d8a;\">Compliance und Qualit\u00e4tssicherung<\/span><\/h3>\n<ul data-pm-slice=\"3 1 []\">\n<li data-rm-block-id=\"block-27\"><b data-path-to-node=\"5,1,0,0\" data-index-in-node=\"0\">Qualit\u00e4tsmanagement nach medizinischen Standards:<\/b> Alle Produktionslinien unterliegen strengen <b data-path-to-node=\"5,1,0,0\" data-index-in-node=\"76\">ISO 13485<\/b> Qualit\u00e4tsmanagementstandards f\u00fcr Medizinprodukte. Wir gew\u00e4hrleisten mikroskopische Chargenkonsistenz und R\u00fcckverfolgbarkeit auf Komponentenebene gem\u00e4\u00df 100%, um den Anforderungen globaler beh\u00f6rdlicher Inspektionen im medizinischen Bereich gerecht zu werden.<\/li>\n<\/ul>\n<ul data-pm-slice=\"3 1 []\">\n<li data-rm-block-id=\"block-28\"><b data-path-to-node=\"5,1,1,0\" data-index-in-node=\"0\">Weltweite Einhaltung von Umwelt- und Materialvorschriften:<\/b> Wir bieten umfassende Unterst\u00fctzung bei der Dokumentation f\u00fcr weltweite beh\u00f6rdliche Zulassungen (FDA, CE und MDR). Dazu geh\u00f6ren die vollst\u00e4ndige Einhaltung der Vorschriften und die fristgerechte Einreichung von Unterlagen f\u00fcr <b data-path-to-node=\"5,1,1,0\" data-index-in-node=\"197\">CMRT 6.5 (Meldevorlage f\u00fcr Konfliktmineralien)<\/b> und <b data-path-to-node=\"5,1,1,0\" data-index-in-node=\"249\">EMRT 2.1 (Erweiterte Vorlage f\u00fcr die Mineralienberichterstattung)<\/b>, wodurch vollst\u00e4ndige Transparenz in Ihrer Lieferkette gew\u00e4hrleistet wird.<\/li>\n<\/ul>\n<ul data-pm-slice=\"3 1 []\">\n<li data-rm-block-id=\"block-29\"><b data-path-to-node=\"5,1,2,0\" data-index-in-node=\"0\">Agiles Rahmenwerk f\u00fcr die Produktneueinf\u00fchrung (NPI) und die HMLV-Produktion:<\/b> Unsere Einrichtung unterst\u00fctzt die <b data-path-to-node=\"5,1,2,0\" data-index-in-node=\"71\">High-Mix, Low-Volume (HMLV)<\/b> Modell. Wir unterst\u00fctzen Ihre Innovation mit einem engagierten <b data-path-to-node=\"5,1,2,0\" data-index-in-node=\"146\">NPI (Einf\u00fchrung neuer Produkte)<\/b> Entwicklungsteam, das die schnelle Prototypenerstellung, die erste Verifizierung und die nahtlose Skalierung beschleunigt.<\/li>\n<\/ul>\n<h3 data-pm-slice=\"1 1 []\" data-rm-block-id=\"block-30\"><span style=\"color: #0c4d8a;\">Technische Daten<\/span><\/h3>\n<p data-rm-block-id=\"block-32\">\n<table id=\"tablepress-4\" class=\"tablepress tablepress-id-4\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Feature<\/th><th class=\"column-2\">Available Specifications<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Application<\/td><td class=\"column-2\">Core needles for IV Cannula, Indwelling Catheters, Introducer Systems.<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Material Options<\/td><td class=\"column-2\">Premium Stainless Steel (SUS304, SUS316L), Cobalt-Chromium, etc.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Diameter Range<\/td><td class=\"column-2\">Custom micro-tubing diameters tailored to standard medical gauges (14G - 26G).<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Wall Thickness<\/td><td class=\"column-2\">Regular Wall (RW), Thin Wall (TW), Ultra-Thin Wall (UTW down to 0.06mm).<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Bending Tolerances<\/td><td class=\"column-2\">Tight angle control \u00b11 degrees and strict linear tolerances according to your drawings.<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Surface Finish<\/td><td class=\"column-2\">Advanced electropolishing, passivation, and optional anti-friction coatings (Silicone\/PTFE).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/p>\n<p data-path-to-node=\"7,0,0\" data-rm-block-id=\"block-33\">","protected":false},"excerpt":{"rendered":"<p>Optimized for IV Indwelling: Specifically engineered as high-precision inner needles for advanced intravenous indwelling systems.<\/p>\n<p>Non-Coring &amp; Non-Traumatic: Ultra-sharp, precision-ground needle bevel prevents tissue coring and minimizes vascular trauma during venipuncture.<\/p>\n<p>Flawless Custom Bending: Advanced multi-angle bending technology guarantees 100% open internal channels (no wrinkling or flattening) for optimal blood flashback and fluid flow.<\/p>\n<p>Flexible OEM\/ODM Prototyping: Full support for custom lengths, diameters, wall thicknesses (down to ultra-thin), and specialized geometries under ISO 13485.<\/p>","protected":false},"featured_media":4281,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"normal-width-container","site-content-style":"boxed","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[28],"product_cat":[90],"product_tag":[],"class_list":["post-4280","product","type-product","status-publish","has-post-thumbnail","product_brand-lij-med-tube","product_cat-puncture-intervention","desktop-align-left","tablet-align-left","mobile-align-left","ast-product-gallery-layout-horizontal-slider","ast-product-tabs-layout-horizontal","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/product\/4280","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/comments?post=4280"}],"version-history":[{"count":4,"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/product\/4280\/revisions"}],"predecessor-version":[{"id":4287,"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/product\/4280\/revisions\/4287"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/media\/4281"}],"wp:attachment":[{"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/media?parent=4280"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/product_brand?post=4280"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/product_cat?post=4280"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lijmedtube.com\/de\/wp-json\/wp\/v2\/product_tag?post=4280"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}